Call us on +44 (0)1793 824111 or email sales@amcs.co.uk

Gas Analysis - Environmental

Search Products

Looking for a product? Search here

Product Listings

COMBUSTION – AMETEK CMFA

Versatile pre-combustion or Flue Gas analyser commonly used for spot sampling gas melting tanks, mix station tuning on forehearths, furnace atmosphere control and flame treating applications.

COMBUSTION – AMETEK PACE 400

The Thermox PACE2 400 is an easy-to-use industrial-grade combustion efficiency and environmental analyser that calculates the combustion efficiency of furnaces, boilers and other industrial combustion equipment.

CWD 2005 Heating Value Transmitter

The CWD 2005 is a high speed process gas analyser for monitoring and control of Calorific value, Wobbe Index and Specific gravity and as an option, the Air/Fuel ratio of process gas.

EMISSIONS – LAND FGA II

The FGA II continuous emissions monitor uses Advanced Dual Sensor Technology (ADST) to measure specific flue gas components.

INCA 4000 (lines 2 - 8)

Discontinuous measurement. The instrument is equipped with a process gas cooler and can have up to 8 measuring points.The components methane (CH4), carbon dioxide (CO2), oxygen (O2) and hydrogen sulfide (H2S) are analyzed in condensate free or wet gas. The gas is aspirated from the measuring points, which can be at a distance of up to 100 m. Two calibration gas inputs allow time-controlled periodic calibrations. The patented μPulse technique leads to an extended lifetime of the H2S sensor.

INCA 4000 T100 Gas Analyzer for Biogas/Biomethane

Discontinuous measurement.The instrument is equipped with a process gas cooler. The components methane (CH4), carbon dioxide (CO2), oxygen (O2) and hydrogen sulfide (H2S) are analyzed in condensate free or wet gas.

LASER – NEO LASERGAS II

The LaserGas II Single Path (SP) monitor from NEO Monitors  is a compact, high performance gas monitor for true continuous in-situ monitoring. Based on the well-proven tuneable diode laser (TDLAS)

LaserGas III Portable HF Analyser

NEO Monitors new portable analyser is compact, lightweight, and battery powered for HF measurement on the spot (other gases such as HCl, NH3, H2S on request).

LaserGas III Single Path Oxygen Analyser

Key Features

  • Gen. 3 compact LaserGas electronics
  • For operation in zone 1 and class I div 1 areas
  • Sub second response times
  • Low power < 10 Watt
  • Suitable for use in SIL 2 systems
  • No interference from other gases
  • Stable calibration, no zero drift
  • No gas sampling: In-situ measurement

Model 881-NSL H2S in Sulfur Pit Analyzer

AMETEK's No Sample Line technology for the sulfur pit. The 881-NSL has no costly troublesome external sample line. The analyzer mounts directly on your sulfur pit lid, eliminating sample line plugging, the number one problem in Claus Plant analysis. The 881-NSL photometer combines an extraordinary long lamp life (estimated 5 years!) with many innovative features designed to minimize maintenance and increase reliability. The 881-NSL is equipped with anti-clogging blowback features. Any out-of-range condition automatically initiates air blowback to clear the sample system. This feature minimizes the chance of costly downtime by reducing sample line plugging. The analyzer continuously monitors itself for proper operation and has built-in alarm features.

Model 909 Hot/wet Single Gas Mass Flow CEM

The analyzer is specifically configured for monitoring stack emissions on a mass rate basis. It measures stack effluent temperature and velocity in addition to pollutant concentrations at stack conditions enabling mass emission rates to be reported.

Model 910 Hot/wet Multi-Gas CEM

The Model 910 is a version of the Model 920 specifically configured for monitoring stack emissions on a mass rate basis. The standard configuration measures stack effluent temperature and velocity in addition to pollutant concentrations at stack conditions, enabling mass emission rates to be reported.

Model 919 Hot/wet Single Gas Analyzer

The Model 919 is a UV-based photometric analyzer capable of measuring any one of hundreds of UV-absorbing compounds. The 919 is a complete system with a sample extraction and transport system designed to maintain sample integrity.

Model 920 Multi-Gas Analyzer

The Model 920 is a multi-component analyzer capable of measuring up to five different gases simultaneously. It, therefore, performs analyses typically requiring two or more separate analyzers.

OXYGEN – AMETEK THERMOX

The Thermox PreMix 2000 analyzer accurately and continuously measures the proportions of oxygen and fuel in pre-mix gases, operating in either excess fuel or excess air conditions. The analyzer is fed a small sample of the air/fuel mixture, burns it and then measures the net oxygen or net excess fuel content of the mixture.

Pury 250e Gas Purification System

The Pury 250e gas purification system dries and cleans gas in such a way that it can be processed for measurement in a CWD2000 gas calorimeter or other on-line process analyzers.

TAIL GAS – AMETEK 880 NSL

Accurate, reliable measurement of H2S and SO2 in the tail gas from a Claus sulfur recovery plant is critical. Unfortunately, tail gas analysis has historically been one of the most difficult applications because of common problems with sample line plugging due to sulfur vapors present in the sample.

TAIL GAS – AMETEK MODEL 900

AMETEK’s Western Research Model 900 Air Demand Analyzer was specifically designed for Claus processes and to meet the more demanding analytical requirements of these new processes. Used in conjunction with the ASR 900 sampling probe, which provides trouble-free sampling, the Model 900 ensures maximum data availability for optimum operation of all sulfur recovery processes. SO2.